modelStaticCentrifugalPump

Water solution static centrifugal pump

Information

## Copyright © EDF 2002 - 2026   
## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
ThermoSysPro.Units.nonSI.AngularVelocity_rpmVRot1400Rotational speed
ThermoSysPro.Units.nonSI.AngularVelocity_rpmVRotn1400Nominal rotational speed
Realrm0.85Product of the pump mechanical and electrical efficiencies
Booleanadiabatic_compressionfalsetrue: adiabatic compression - false: non adiabatic compression
Units.SI.Densityrho1000Fluid density
Reala1-88.67x^2 coef. of the pump characteristics hn = f(vol_flow) (s2/m5)
Reala20x coef. of the pump characteristics hn = f(vol_flow) (s/m2)
Reala343.15Constant coef. of the pump characteristics hn = f(vol_flow) (m)
Realb1-3.7751x^2 coef. of the pump efficiency characteristics rh = f(vol_flow) (s2/m6)
Realb23.61x coef. of the pump efficiency characteristics rh = f(vol_flow) (s/m3)
Realb3-0.0075464Constant coef. of the pump efficiency characteristics rh = f(vol_flow) (s.u.)

Connectors

TypeNameDefaultDescription
ThermoSysPro.WaterSolution.Connectors.WaterSolutionInletC1
ThermoSysPro.WaterSolution.Connectors.WaterSolutionOutletC2
ThermoSysPro.InstrumentationAndControl.Connectors.InputLogicalcommandePompe
ThermoSysPro.InstrumentationAndControl.Connectors.InputRealVRotation

Components

TypeNameDefaultDescription
RealrhHydraulic efficiency
Units.SI.LengthhnPump head
RealRRatio VRot/VRotn (s.u.)
Units.SI.MassFlowRateQMass flow
Units.SI.VolumeFlowRateQvVolumetric flow
Units.SI.PowerWhHydraulic power
Units.SI.PowerWmMotor power
Units.SI.AbsolutePressuredeltaPPressure difference between the outlet and the inlet
Units.SI.SpecificEnthalpyh1Fluid specific enthalpy at the inlet
Units.SI.SpecificEnthalpyh2Fluid specific enthalpy at the outlet
Units.SI.SpecificEnthalpydeltaHSpecific enthalpy variation between the outlet and the inlet

Revisions

Author  

Daniel Bouskela