modelStaticCentrifugalPump
Water solution static centrifugal pump
Information
## Copyright © EDF 2002 - 2026
## ThermoSysPro Version 4.2
Parameters
| Type | Name | Default | Description |
| ThermoSysPro.Units.nonSI.AngularVelocity_rpm | VRot | 1400 | Rotational speed |
| ThermoSysPro.Units.nonSI.AngularVelocity_rpm | VRotn | 1400 | Nominal rotational speed |
| Real | rm | 0.85 | Product of the pump mechanical and electrical efficiencies |
| Boolean | adiabatic_compression | false | true: adiabatic compression - false: non adiabatic compression |
| Units.SI.Density | rho | 1000 | Fluid density |
| Real | a1 | -88.67 | x^2 coef. of the pump characteristics hn = f(vol_flow) (s2/m5) |
| Real | a2 | 0 | x coef. of the pump characteristics hn = f(vol_flow) (s/m2) |
| Real | a3 | 43.15 | Constant coef. of the pump characteristics hn = f(vol_flow) (m) |
| Real | b1 | -3.7751 | x^2 coef. of the pump efficiency characteristics rh = f(vol_flow) (s2/m6) |
| Real | b2 | 3.61 | x coef. of the pump efficiency characteristics rh = f(vol_flow) (s/m3) |
| Real | b3 | -0.0075464 | Constant coef. of the pump efficiency characteristics rh = f(vol_flow) (s.u.) |
Revisions
Author
Daniel Bouskela