modelStaticCentrifugalPumpNom
Static centrigugal pump with nominal operating point
Information
## Copyright © EDF 2002 - 2026 ## ThermoSysPro Version 4.2
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Units.SI.MassFlowRate | Qnom | 1 | Nominal mass flow |
| ThermoSysPro.Units.SI.PressureDifference | DPnom | 1e5 | Nominal pressure increase |
| Real | A | 0.15 | x^2 coef. of the pump characteristics (A>0) |
| Real | B | 0.35 | x coef. of the pump characteristics (B>0) |
| Real | eta | 0.9 | Hydraulic efficiency |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Connectors.WaterSolutionInlet | Ce | ||
| Connectors.WaterSolutionOutlet | Cs |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| ThermoSysPro.Units.SI.PressureDifference | deltaP | Pressure difference between the outlet and the inlet | |
| Units.SI.SpecificEnthalpy | He | Fluid specific enthalpy at the inlet | |
| Units.SI.SpecificEnthalpy | Hs | Fluid specific enthalpy at the outlet | |
| Units.SI.Power | W | Mechanical power of the pump |
Revisions
Author Benoît Bride