modelStaticCentrifugalPumpNom

Static centrigugal pump with nominal operating point

Information

## Copyright © EDF 2002 - 2026  


## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
Units.SI.MassFlowRateQnom1Nominal mass flow
ThermoSysPro.Units.SI.PressureDifferenceDPnom1e5Nominal pressure increase
RealA0.15x^2 coef. of the pump characteristics (A>0)
RealB0.35x coef. of the pump characteristics (B>0)
Realeta0.9Hydraulic efficiency

Connectors

TypeNameDefaultDescription
Connectors.WaterSolutionInletCe
Connectors.WaterSolutionOutletCs

Components

TypeNameDefaultDescription
ThermoSysPro.Units.SI.PressureDifferencedeltaPPressure difference between the outlet and the inlet
Units.SI.SpecificEnthalpyHeFluid specific enthalpy at the inlet
Units.SI.SpecificEnthalpyHsFluid specific enthalpy at the outlet
Units.SI.PowerWMechanical power of the pump

Revisions

Author  

Benoît Bride