Steam dryer
## Copyright © EDF 2002 - 2026
## ThermoSysPro Version 4.2
This component model is documented in Sect. 14.9 of the ThermoSysPro book.
# Steam dryer
The steam dryer is a reservoir of steam and water used to separate water from the steam generated in the boiler.
Indeed, wet steam (steam containing some liquid) can reduce the
plant efficiency and cause damage to most items and equipment of the plant.
Following assumptions are made:
- heat exchange between the liquid and steam phases is neglected.
- heat exchange between the steam dryer and the external medium is neglected.
- pressure losses are neglected.
## Modelica component model
The equations mentioned below are implemented in the component *SteamDryer*, located in the *WaterSteam.Junctions* sub-library.
This component has 3 connectors:
- Cev: vapor inlet,
- Csl: liquid outlet,
- Csv: vapor outlet.

## Nomenclature
| Symbol| Description| Unit| Definition | Modelica name |
| :----------------------------- | :------------------------------------------------------- | :--------------------------- | :---------------------- | :----------- |
| \\(h\_{\mathrm{i}}\\)| Specific enthalpy of the fluid at the inlet of the dryer | \\(\mathrm{J} / \mathrm{kg}\\) || Cev.h |
| \\(h\_{l, \mathrm{o}}\\)| Specific enthalpy of the liquid at the outlet| \\(\mathrm{J} / \mathrm{kg}\\) || Cs1.h |
| \\(h\_{l}^{\mathrm{sat}}\\)| Saturation enthalpy of the liquid| \\(\mathrm{J} / \mathrm{kg}\\) || lsat1.h |
| \\(h\_{\mathrm{v}, \mathrm{o}}\\) | Specific enthalpy of the steam at the outlet| \\(\mathrm{J} / \mathrm{kg}\\) || Csv.h |
| \\(\dot{m}\_{\mathrm{i}}\\)| Fluid mass flow rate at the inlet| \\(\mathrm{kg} / \mathrm{s}\\) || Cev.Q |
| \\(\dot{m}\_{l, \mathrm{o}}\\)| Liquid mass flow rate at the outlet| \\(\mathrm{kg} / \mathrm{s}\\) || Cs1.Q |
| \\(m\_{\mathrm{v}, \mathrm{o}}\\) | Steam mass flow rate at the outlet| \\(\mathrm{kg} / \mathrm{s}\\) || Csv.Q |
| \\(P\\)| Fluid pressure in the dryer| \\(\mathrm{Pa}\\)|| P |
| \\(x\_{\mathrm{i}}\\)| Steam mass fraction at the inlet| \\(-\\)|| xe |
| \\(\eta\\)| Steam dryer efficiency| \\(-\\)| \\(0 \leq \eta \leq 1\\)| eta |
## Governing equations
### Static mass balance equation
- Validity domain:
\\(\forall \dot{m}\\)
- Mathematical formulation:
$$0=\dot{m}\_{\mathrm{i}}-\dot{m}\_{l, \mathrm{o}}-\dot{m}\_{\mathrm{v}, \mathrm{o}}$$
- Comments :
The value of the steam mass flow rate at the outlet
\\(\left\(\dot{m}\_{\mathrm{v}, \mathrm{o}}\right\)\\) is given by
$$ \dot{m}_{\mathrm{v}, \mathrm{o}}=\left\{\begin{array}{ll} 0 \text{ for } x_{\mathrm{i}}=0 \\ \dot{m}_{\mathrm{i}} \cdot\left(1-\eta \cdot\left(1-x_{\mathrm{i}}\right)\right) \text{ for } x_{\mathrm{i}}>0 \end{array}\right.$$
In a real steam separator, small quantities of liquid remain in the steam.
The efficiency gives the discrepancy between ideal and real steam separator.
### Static energy balance equation
- Validity domain:
\\(\exists \dot{m}\\) such that \\(\dot{m} \neq 0\\)
- Mathematical formulation:
$$0=\dot{m}\_{\mathrm{i}} \cdot h\_{\mathrm{i}}-\dot{m}\_{l, \mathrm{o}} \cdot h\_{l, \mathrm{o}}-\dot{m}\_{\mathrm{v}, \mathrm{o}} \cdot h\_{\mathrm{v}, \mathrm{o}}$$
- Comments:
This equation is valid if not all mass flow rates are equal to zero. Otherwise, the mixing specific enthalpy inside the steam dryer is undefined. The value of the specific enthalpy of the liquid at the outlet \\(h\_{l,0}\\) is given by:
$$ h_{1, \mathrm{o}}=\left\{\begin{array}{ll}h_{1}^{\mathrm{sat}} \text{ for } x_{\mathrm{i}}>0 \\ h_{\mathrm{i}} \text{ for } x_{\mathrm{i}}=0\end{array}\right.$$