modelSteamEngine

Steam engine

Information

## Copyright © EDF 2002 - 2026   
## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
Real[:,2]caract[0, 0; 15e5, 20.0]Engine charateristics Q=f(deltaP)
Realeta_is0.85Isentropic efficiency
RealW_frot0.0Power losses due to hydrodynamic friction (percent)
Realeta_stato1.0Efficiency to account for cinetic losses (<= 1) (s.u.)
Integeroption_interpolation11: linear interpolation - 2: spline interpolation
Integermode_e0Inlet IF97 region. 1:liquid - 2:steam - 4:saturation line - 0:automatic
Integermode_s0Outlet IF97 region. 1:liquid - 2:steam - 4:saturation line - 0:automatic

Connectors

TypeNameDefaultDescription
Connectors.FluidInletC1
Connectors.FluidOutletC2

Components

TypeNameDefaultDescription
Units.SI.PowerWPower produced by the engine
Units.SI.MassFlowRateQMass flow rate
Units.SI.SpecificEnthalpyHisFluid specific enthalpy after isentropic expansion
ThermoSysPro.Units.SI.PressureDifferencedeltaPPressure loss
Units.SI.AbsolutePressurePePressure at the inlet
Units.SI.AbsolutePressurePsPressure at the outlet
Units.SI.TemperatureTeTemperature at the inlet
Units.SI.TemperatureTsTemperature at the outlet
RealxmAverage vapor mass fraction (n.u.)
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_phproe
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_phpros
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_psprops

Revisions

Authors  

Benoît Bride  
Daniel Bouskela