modelInvSingularPressureLoss

Inverse singular pressure loss

Information

## Copyright © EDF 2002 - 2026  


## ThermoSysPro Version 4.2

Parameters

TypeNameDefaultDescription
Booleancontinuous_flow_reversalfalsetrue: continuous flow reversal - false: discontinuous flow reversal
Integerfluid11: water/steam - 2: C3H3F5
Units.SI.Densityp_rho0If > 0, fixed fluid density
Integermode0IF97 region. 1:liquid - 2:steam - 4:saturation line - 0:automatic

Connectors

TypeNameDefaultDescription
Connectors.FluidInletC1
Connectors.FluidOutletC2

Components

TypeNameDefaultDescription
RealKPressure loss coefficient
ThermoSysPro.Units.SI.PressureDifferencedeltaPSingular pressure loss
Units.SI.MassFlowRateQMass flow rate
Units.SI.DensityrhoFluid density
Units.SI.TemperatureTFluid temperature
Units.SI.AbsolutePressurePmAverage fluid pressure
Units.SI.SpecificEnthalpyhFluid specific enthalpy
ThermoSysPro.Properties.WaterSteam.Common.ThermoProperties_phpro

Revisions

Authors  

Baligh El Hefni  
Daniel Bouskela