modelPump
Pump model with different adiabatic models (FullMedium, IncompressibleFluid, IsothermalReference)
Extends from Modelica.Icons.Example (Icon for runnable examples), ThermofluidStream.Idealized.Utilities.IconInertanceNeglect (Icon for considerInertance = false).
Information
Forward and inverse calculations of different adiabatic models (FullMedium, IncompressibleFluid, IsothermalReference) for a pump are demonstrated:
-
P(m_flow, p_out) -
p_out(m_flow, P) -
m_flow(p_out, P)
fullMedium2 requires considerInertance = false if p_out is time-dependent.
The calculation m_flow := P/dh fails for dh = 0.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| SI.Efficiency | eta | 0.8 | Isentropic efficiency |
Components
Contents
| Name | Description |
|---|---|
Revisions
-
2026, by Raphael Gebhart (raphael.gebhart@dlr.de):
Initial version.