Dynamic viscosity w.r.t. temperature and density | use setState_phX function for input
This function calculates the dynamic viscosity of R134a from the state record (e.g., use setState_phX function for input). The dynamic viscosity is modelled by the corresponding states method of Klein, McLinden and Laesecke (1997).
Restrictions
This property is only defined in one-phase region.
References
- Klein, McLinden and Laesecke:
- An improved extended corresponding states method for estimation of visocsity of pure refrigerants and mixtures.
Int. J. Refrig., Vol. 20, No.3, pp. 208-217, 1997.
eta-Diagram-R134a.png)
Generated at 2025-03-08T19:24:39Z
by OpenModelicaOpenModelica 1.24.5 using GenerateDoc.mos