.ThermofluidStream.Processes.Pipes.Interfaces.SISOFlow_nonConstArea

Information

Extended version of SISOFlow to restore Bernoulli's principle (change of static pressure due to change of velocity), i.e. diffusors (different crosssectional area of inlet and outlet).

p_out = p_in + dq + dp

Change of static pressure due to change of velocity dq:

dq = rho/2 * (c_in^2 - c_out^2)

[P. Jordan; HTWG Konstanz; 01/24]

HTWG Konstanz

Contents

NameDescription
 MediumMedium model

Generated at 2024-12-04T19:25:49Z by OpenModelicaOpenModelica 1.24.2 using GenerateDoc.mos