modelJunctionN

Junction with N inlets and one outlet

Extends from ThermofluidStream.Utilities.DropOfCommonsPlus (Extend this to use 'dropOfCommons', 'instanceName', 'displayInstanceName' and 'displayParameters').

Information

Generic junction with an array of N upstream connections and one downstream connection. Use this model for parameterized merge structures.

considerInertance

The model is not suitable for the parameter considerInertance; see Idealized.UsersGuide.InertanceNeglect and compare with Idealized.Topology. In a future version, the Idealized junction models may be integrated into this model.

Parameters

TypeNameDefaultDescription
StringinstanceName (from DropOfCommonsPlus)getInstanceName()Instance name
IntegerN1Number of inlets
BooleanassumeConstantDensitytrue= true, if mixture states are determined by mass flow rates
Layout
BooleandisplayInstanceName (from DropOfCommonsPlus)dropOfCommons.displayInstanceNames= true, if instance name is displayed
BooleandisplayParameters (from DropOfCommonsPlus)dropOfCommons.displayParameters= true, if displaying parameters is enabled
Advanced
SI.MassFlowRatem_flow_epsdropOfCommons.m_flow_regRegularization threshold for small mass flows
Utilities.Units.InertanceLdropOfCommons.LInertance of each inlet/outlet

Connectors

TypeNameDefaultDescription
Interfaces.Inlet[N]inletsVector of N inlets
Interfaces.OutletoutletOutlet

Components

TypeNameDefaultDescription
Real[N]wRegularized weighting factor for specific enthalpy
Medium.Density[N]rhoMedium.density(inlets.state)Density at inlets

Contents

NameDescription
MediumMedium model
mfkprotected