modelJunctionRatio

Split-ratio Junction for a bypass

Extends from ThermofluidStream.Utilities.DropOfCommonsPlus (Extend this to use 'dropOfCommons', 'instanceName', 'displayInstanceName' and 'displayParameters').

Information

A junction with a fixed mass-flow split. It can be understood to use energy of the higher-pressure inlet to pull the lower-pressure stream (likely to dynamic pressure effects).

For SplitterRatio and JunctionRatio make to only prescribe mass-flow-split in Splitter or Junction.

Parameters

TypeNameDefaultDescription
StringinstanceName (from DropOfCommonsPlus)getInstanceName()Instance name
BooleanassumeConstantDensitytrue= true, if mixture states are determined by mass flow rates
SI.TimeTC_input0.05Time constant
Booleaninvertfalse= true, if splitRatio input is inverted (1-splitRatio)
Layout
BooleandisplayInstanceName (from DropOfCommonsPlus)dropOfCommons.displayInstanceNames= true, if instance name is displayed
BooleandisplayParameters (from DropOfCommonsPlus)dropOfCommons.displayParameters= true, if displaying parameters is enabled
Advanced
SI.MassFlowRatem_flow_epsdropOfCommons.m_flow_regRegularization threshold for small mass flows
Utilities.Units.InertanceLdropOfCommons.LInertance of each inlet/outlet

Connectors

TypeNameDefaultDescription
Interfaces.Outletoutlet
Interfaces.InletinletA
Interfaces.InletinletB
Modelica.Blocks.Interfaces.RealInputsplitRatio

Contents

NameDescription
MediumMedium model
mfkprotected