modelTwoPhaseSensorSelect

Selectable sensor for two phase medium

Extends from Internal.PartialSensor (Partial undirected sensor).

Information

Undirected sensor for a vapor quality. It must be separate from SingleSensorSelect, because it needs a TwoPhaseMedium.

Parameters

TypeNameDefaultDescription
StringinstanceName (from DropOfCommonsPlus)getInstanceName()Instance name
QuantitiesquantityMeasured quantity
StringquantityStringif quantity == ThermofluidStream.Sensors.Internal.Types.TwoPhaseQuantities.x_kgpkg then "x in kg/kg" elseif quantity == ThermofluidStream.Sensors.Internal.Types.TwoPhaseQuantities.T_sat_K then "T_sat in K" elseif quantity == ThermofluidStream.Sensors.Internal.Types.TwoPhaseQuantities.T_sat_C then "T_sat in °C" elseif quantity == ThermofluidStream.Sensors.Internal.Types.TwoPhaseQuantities.p_sat_Pa then "p_sat in Pa" elseif quantity == ThermofluidStream.Sensors.Internal.Types.TwoPhaseQuantities.p_sat_bar then "p_sat in bar" elseif quantity == ThermofluidStream.Sensors.Internal.Types.TwoPhaseQuantities.T_oversat_K then "T - T_sat in K" elseif quantity == ThermofluidStream.Sensors.Internal.Types.TwoPhaseQuantities.p_oversat_Pa then "p - p_sat in Pa" elseif quantity == ThermofluidStream.Sensors.Internal.Types.TwoPhaseQuantities.p_oversat_bar then "p - p_sat in bar" else "error"
Layout
BooleandisplayInstanceName (from DropOfCommonsPlus)dropOfCommons.displayInstanceNames= true, if instance name is displayed
BooleandisplayParameters (from DropOfCommonsPlus)dropOfCommons.displayParameters= true, if displaying parameters is enabled
Sensor display
Integerdigits (from PartialSensor)3Number of significant digits to be displayed
Advanced › Regularization
SI.MassFlowRatem_flow_reg (from PartialSensor)dropOfCommons.m_flow_regRegularization threshold of mass flow rate
Output
BooleanoutputValuefalse= true, if sensor output is enabled
Booleanfilter_outputfalse= true, if sensor output is filtered (to break algebraic loops)
SI.TimeTC0.1Time constant of sensor output filter (PT1)
InitModeinitInitMode.steadyStateInitialization mode for sensor output
Realvalue_00Start value of sensor output

Connectors

TypeNameDefaultDescription
Interfaces.Rearrear (from PartialSensor)
Interfaces.Forefore (from PartialSensor)
Modelica.Blocks.Interfaces.RealOutputvalue_outvalueSensor output connector

Components

TypeNameDefaultDescription
Medium.ThermodynamicStatestate (from PartialSensor)Medium.setState_phX(p_reg, h_reg, Xi_reg)
Realvalue

Contents

NameDescription
Medium2PhaseMedium model
getQuantityprotectedQuantity compute function