.TransiEnt.Basics.Adapters.Gas.RealNG7_SG_to_RealSG6

Information

Adapter for switching from real gas NG7_SG to real gas SG6 fluid models

1. Purpose of model

This model represents an adapter to switch from real gas NG7_SG to real gas SG6 fluid models.

2. Level of detail, physical effects considered, and physical insight

Temperature, pressure and mass flow stay the same. The model only works in the design flow direction.

3. Limits of validity

Only valid for one-phase real gas NG7_SG and real gas SG6 fluid models. Also, the NG7_SG fluid can only contain SG6 components so Ethane, Propane and Butane are not allowed in the NG7_SG fluid.

4. Interfaces

gasPortIn: inlet port for real gas NG7_SG

gasPortOut: outlet port for real gas SG6

5. Nomenclature

(no elements)

6. Governing Equations

(no equations)

7. Remarks for Usage

It is important to ensure that the flow is always in the design flow direction and that Ethane, Propane and Butane are not present in the NG7_SG fluid.

8. Validation

Tested in check model "TestRealGasAdapters"

9. References

(no remarks)

10. Version History

Model created by Carsten Bode (c.bode@tuhh.de) on Tue Apr 05 2016


Generated at 2024-10-21T18:25:38Z by OpenModelicaOpenModelica 1.24.0 using GenerateDoc.mos