.TransiEnt.Basics.Adapters.Gas.RealNG7_to_RealNG7_SG

Information

Adapter for switching from real gas NG7 to real gas NG7_SG fluid models

1. Purpose of model

This model represents an adapter to switch from real gas NG7 to real gas NG7_SG fluid models.

2. Level of detail, physical effects considered, and physical insight

Temperature, pressure and mass flow stay the same. The model only works in the design flow direction.

3. Limits of validity

Only valid for real gas NG7 and real gas NG7_SG fluid models.

4. Interfaces

gasPortIn: inlet port for real gas NG7

gasPortOut: outlet port for real gas NG7_SG

5. Nomenclature

(no elements)

6. Governing Equations

(no equations)

7. Remarks for Usage

It is important to ensure that the flow is always in the design flow direction.

8. Validation

Tested in check model "TestRealGasAdapters"

9. References

(no remarks)

10. Version History

Model created by Carsten Bode (c.bode@tuhh.de) on Tue Apr 05 2016


Generated at 2024-10-21T18:25:38Z by OpenModelicaOpenModelica 1.24.0 using GenerateDoc.mos