.TransiEnt.Basics.Adapters.Gas.RealNG7_to_RealSG4

Information

Adapter for switching from real gas NG7_H2_var to real gas SG4_var fluid models

1. Purpose of model

This model represents an adapter to switch from NG7_H2_var to real gas SG4_var fluid models.

2. Level of detail, physical effects considered, and physical insight

Temperature, pressure and mass flow stay the same. The model only works in the design flow direction.

3. Limits of validity

Only valid for one-phase real gas NG7_H2_var and real gas SG4_var fluid models.

4. Interfaces

gasPortIn: inlet port for real gas NG7_H2_var

gasPortOut: outlet port for real gas SG4_var

5. Nomenclature

(no elements)

6. Governing Equations

(no equations)

7. Remarks for Usage

It is important to ensure that the flow is always in the design flow direction.

8. Validation

Tested in check model "TestRealGasAdapters"

9. References

(no remarks)

10. Version History

Model created by Carsten Bode (c.bode@tuhh.de) on Tue Apr 05 2016