.TransiEnt.Components.Boundaries.Electrical.ComplexPower.PVBoundary

Information

1. Purpose of model

Model for PU bus when using ComplexPowerPort for LoadFlowCalculations

2. Level of detail, physical effects considered, and physical insight

L1E (defined in the CodingConventions), Voltage (only magnitude) and active Power are fixed

3. Limits of validity

stationary component that balances reactive power perfectly respectively to the flows in the grid

4. Interfaces

ComplexPowerPort

P_el_set: input for electric power in [W]

5. Nomenclature

Angle delta_pugen

Q_gen(start=0) "Reactive Power of Plant, Load Flow"

f(start=simCenter.f_n) "frequency"

6. Governing Equations

(no equations)

7. Remarks for Usage

Use for stationary load flow calculations

8. Validation

validated by Jan-Peter Heckel (jan.heckel@tuhh.de)

9. References

(no remarks)

10. Version History

Model created by Jan-Peter Heckel (jan.heckel@tuhh.de) in January 2018

Input connector added in July 2018 and April 2019


Generated at 2024-10-21T18:25:38Z by OpenModelicaOpenModelica 1.24.0 using GenerateDoc.mos