modelFluidSource
Mass flow boundary for new connector
Extends from TransiEnt.Basics.Icons.BoundaryVLE_flow.
Information
Purpose of model
A simple model of a fluid source that can be used as a boundary for fluid simulations. It consists of a fluid outlet. A mass flow flowing out or into the component is set with a RealInput. If the RealInput of the mass flow has a positive sign, the mass flow is flowing out of the boundary. A specific enthalpy is set with a RealInput.
Interfaces
port_a: fluid outlet
h_in: RealInput for the specifici enthalpy that shall be set
m_flow_in: RealInput for the mass flow rate that is set
Version History
Model was inserted by Jan Westphal (j.westphal@tuhh.de) January 2025
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| SI.MassFlowRate | m_flow | 1 | Mass flow rate (unused) |
| SI.SpecificEnthalpy | h | 60*4200 | Specific enthalpy of outgoing mass flow rate (unused) |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| TransiEnt.Basics.Interfaces.Thermal.FluidPortOut_simple | port_a | ||
| Modelica.Blocks.Interfaces.RealInput | m_flow_in | ||
| Modelica.Blocks.Interfaces.RealInput | h_in |