This is a dryer which completely separates all the water in the incoming real gas stream.
All the water is separated ideally, no rest humidity is left in the stream. A constant pressure loss is assumed and the temperature is constant. Within the dryer there is no cooling, the cooling has to be done beforehand.
The model is only valid if the remaining water in the stream is negligible.
gasPortIn: real gas inlet
gasPortOut: real gas outlet
fluidPortOut: water outlet
(no elements)
The outgoing water mass flow is calculated using the incoming mass flow and composition. The remaining mass fractions and the mass flow rate are scaled under consideration of the water loss.
The model only works in design flow direction.
Tested in the check model "TestDryer_L1"
(no remarks)
Model created by Carsten Bode (c.bode@tuhh.de) on Tue Apr 05 2016