.TransiEnt.Components.Gas.VolumesValvesFittings.Base.ThreeWayValve_base

Information

1. Purpose of model

This is a partial model for a three way valve for real gas flows. It is a modified version of the model ClaRa.Components.VolumesValvesFittings.Valves.ThreeWayValve_base from ClaRa version 1.3.0. The model is documented there and here only the changes are described.

2. Level of detail, physical effects considered, and physical insight

The two-phase region is deactivated.

3. Limits of validity

Only valid if changes in density and the two-phase region of the fluid can be neglected.

4. Interfaces

TransiEnt.Basics.Interfaces.General.MassFractionIn splitRatio_external(min=0,max=1)=splitRatio if splitRatio_input "Controls mass fraction m2/m1"

TransiEnt.Basics.Interfaces.Gas.RealGasPortIn gasPortIn(Medium=medium) "Inlet port"

TransiEnt.Basics.Interfaces.Gas.RealGasPortOut gasPortOut1(each Medium=medium) "Outlet port"

TransiEnt.Basics.Interfaces.Gas.RealGasPortOut gasPortOut2(each Medium=medium) "Outlet port"

5. Nomenclature

(no elements)

6. Governing Equations

(no remarks)

7. Remarks for Usage

(no remarks)

8. Validation

(no remarks)

9. References

(no remarks)

10. Version History

Model created by Carsten Bode (c.bode@tuhh.de) on Tue Apr 05 2016

Model revised by Carsten Bode (c.bode@tuhh.de) in Apr 2018 (updated to ClaRa 1.3.0)


Generated at 2024-10-22T18:25:24Z by OpenModelicaOpenModelica 1.24.0 using GenerateDoc.mos