1. Purpose of model
Usage in simulation of district heating networks with the traditional parallel supply return layout
2. Level of detail, physical effects considered, and physical insight
(no remarks)
3. Limits of validity
(no remarks)
4. Interfaces
(no remarks)
5. Nomenclature
(no remarks)
6. Governing Equations
(no remarks)
7. Remarks for Usage
For bigger simulations deactivate volume - underestimates the thermal delay by heating / cooling of the steel pipes.
Residence time is limited to 10h to improve initialisation with no mass flow present in the system at time = 0.
Pressure loss is linearized for mass flow rates with 5% of the nominal velocity.
8. Validation
(no remarks)
9. References
Heat transfer based on: B. van der Heijde, M. Fuchs, C. Ribas Tugores "Dynamic equation-based thermo-hydraulic pipe model for district heating and cooling systems", 2017
10. Version History
Model created by Philipp Huismann (huismann@gwi-essen.de) on 10.10.2018
Model revised by Philipp Huismann (huismann@gwi-essen.de) on 07.04.2022 | Pressure Loss linearisation for small mass flow rates, Residence Time limitation
Name | Description |
---|---|
HeatTransfer | HeatTransfer-Model choice for district heating |