modelCheck_SmartMeter

Extends from TransiEnt.Basics.Icons.Checkmodel (Icon for check models).

Information

1. Purpose of model

The purpose of this model is to showcase the model characteristics of TransiEnt.Components.Sensors.SmartMeter. The model has four different SmartMeter configurations included for Ideal, TAF7, TAF10 and Manual measurement characteristics.

2. Level of detail, physical effects considered, and physical insight

(no remarks)

3. Limits of validity

(no remarks)

4. Interfaces

(no remarks)

5. Nomenclature

(no remarks)

6. Governing Equations

(no remarks)

7. Remarks for Usage

Ideal: Values for P, V, I, delta, f, Q are connected to controlBus without noise and without delay.

Manual: Values for P, V, I, delta, f, Q are connected to controlBus with configured noise and delay.

TAF7: Values for P, V, I and E, Q are connected to controlBus with noise and without delay. All values are taken the mean value over 900s and then are sampled by a discrete sampler to get the regulatory required 900s mean values.

TAF10: Values for P, V, I, delta, f, Q are connected to controlBus without noise and without delay. All values are sampled every 60s to get the regulatory required 60s effective values.

8. Validation

(no remarks)

9. References

(no remarks)

10. Version History

Added by Tom Steffen, Techische Universität Hamburg, Institut für Elektrische Energietechnik, 2025

Components

TypeNameDefaultDescription
TransiEnt.Components.Sensors.SmartMeterSmartMeter_TAF7
Modelica.Blocks.Sources.PulsepulseP
Modelica.Blocks.Sources.PulsepulseQ
TransiEnt.Components.Sensors.SmartMeterSmartMeter_TAF10
TransiEnt.Components.Sensors.SmartMeterSmartMeter_Manual
TransiEnt.Components.Sensors.SmartMeterSmartMeter_Ideal
Boundaries.Electrical.ComplexPower.SlackBoundaryvDelta1
Boundaries.Electrical.ComplexPower.PQBoundarypq1
Boundaries.Electrical.ComplexPower.PQBoundarypq2
Boundaries.Electrical.ComplexPower.PQBoundarypq3
Boundaries.Electrical.ComplexPower.PQBoundarypq4