modelGasDemandVarH2_varGCV_controlMFlow

Extends from TransiEnt.Basics.Icons.Checkmodel (Icon for check models).

Information

1. Purpose of model

Test model for the model GasConsumerPipe_HFlow. It shows how the gas demand of the consumers controls the mass flow output of the source. A jump in the composition results in a jump in the mass flows as well.

Also, the maximum possible feed-in mass flow rate of hydrogen is calculated using a sensor.

2. Level of detail, physical effects considered, and physical insight

(no remarks)

3. Limits of validity

(no remarks)

4. Interfaces

(no remarks)

5. Nomenclature

(no remarks)

6. Governing Equations

(no remarks)

7. Remarks for Usage

(no remarks)

8. Validation

(no remarks)

9. References

(no remarks)

10. Version History

Model created by Pascal Dubucq (dubucq@tuhh.de) on 01.10.2014

Components

TypeNameDefaultDescription
TransiEnt.SimCentersimCenter
TransiEnt.Basics.Tables.GasGrid.NaturalGasVolumeFlowSTPgasDemandHFlow
TransiEnt.Consumer.Gas.GasConsumerPipe_HFlowdistrict
TransiEnt.Components.Boundaries.Gas.BoundaryRealGas_pTxisource
TransiEnt.Grid.Gas.Controller.MaxH2MassFlow_phimaxH2MassFlow
TransiEnt.Components.Boundaries.Gas.RealGasCompositionByWtFractions_stepVariationcomposition_linearVariation