recordHouseType55

House type 55 characteristics according to EnEV 2007

Extends from Base.ThermodynamicProperties (record for thermodynamic properties).

Information

1. Purpose of model

record for house type 100 characteristics according to EnEV 2007

2. Level of detail, physical effects considered, and physical insight

(Purely technical component without physical modeling.)

3. Limits of validity

(Purely technical component without physical modeling.)

4.Interfaces

(no remarks)

5. Nomenclature

(no elements)

6. Governing Equations

(no equations)

7. Remarks for Usage

(no remarks)

8. Validation

(no validation or testing necessary)

9. References

[1] Bundesgesetzblatt, "Verordnung über energiesparenden Wärmeschutz und energiesparende Anlagentechnik bei Gebäuden(Energieeinsparverordnung–EnEV)", Bonn, 2007

10. Version History

Parameters

TypeNameDefaultDescription
General Asumptions
Realq_i (from ThermodynamicProperties)5internal heat sources in W/m
Realn_min (from ThermodynamicProperties)0.7minimum needed air change rate
Modelica.Units.SI.Densityrho_air (from ThermodynamicProperties)1.2041Density of air 20C and 1bar
Modelica.Units.SI.SpecificHeatCapacitycp_air (from ThermodynamicProperties)1.005e3specific heat capacity of air
Heat transfer and storage
Realcp_ext (from ThermodynamicProperties)50*3600Heat storage capacity of external walls
Realcp_int (from ThermodynamicProperties)8*3600Heat storage capacity of internal walls
Modelica.Units.SI.CoefficientOfHeatTransferU_ext (from ThermodynamicProperties)0.4Heat transfer coefficient of external walls
Modelica.Units.SI.CoefficientOfHeatTransferU_roof (from ThermodynamicProperties)0.2Heat transfer coefficient of roof
Modelica.Units.SI.CoefficientOfHeatTransferalpha_roomWall (from ThermodynamicProperties)8coefficient of heat transfer from the the air in the room to the walls (typical values 6-8W/mK) for static air
Modelica.Units.SI.CoefficientOfHeatTransferalpha_wallAmbiance (from ThermodynamicProperties)15coefficient of heat transfer from the wall to the environement
Modelica.Units.SI.CoefficientOfHeatTransferalpha_groundsurface (from ThermodynamicProperties)10coefficient of heat transfer from the surface of the ground to the room (can be 10W/mK)