modelPartialDispatchablePowerPlant

Abstract model of an electric power plant with a power setpoint input connector

Extends from PartialElectricPowerPlant (Abstract model of an electric power plant with L1 on electric side).

Information

1. Purpose of model

Prototype model for dispatchable power plant models containing all relevant statistic blocks.

2. Level of detail, physical effects considered, and physical insight

(no remarks)

3. Limits of validity

(no remarks)

4. Interfaces

Type of electrical power port can be chosen

P_el_set: input for electric power in W (electric power setpoint)

5. Nomenclature

(no elements)

6. Governing Equations

(no equations)

7. Remarks for Usage

(no remarks)

8. Validation

(no remarks)

9. References

(no remarks)

10. Version History

Model created by Pascal Dubucq (dubucq@tuhh.de) on 01.10.2014

Model generalized for different electrical power ports by Jan-Peter Heckel (jan.heckel@tuhh.de) in July 2018

Parameters

TypeNameDefaultDescription
IntegernSubgrids (from PartialElectricPowerPlant)simCenter.iDetailedGridFor calculation of statistics in subgrids (=1 local grid, e.g. hamburg, =2 surrounding grid, e.g. UCTE grid
Physical Constraints
Modelica.Units.SI.PowerP_el_n (from PartialElectricPowerPlant)300e6Nominal power of plant
Statistics
Modelica.Units.SI.Efficiencyeta_total (from PartialElectricPowerPlant)0.6Total efficiency of plant for emission calculation
EnergyResourcetypeOfResource (from PartialElectricPowerPlant)EnergyResource.ConventionalType of energy resource for global model statistics
PrimaryEnergyCarriertypeOfPrimaryEnergyCarrier (from PartialElectricPowerPlant)PrimaryEnergyCarrier.BlackCoalType of primary energy carrier for co2 emissions global statistics
BooleanintegrateElPower (from PartialElectricPowerPlant)simCenter.integrateElPowertrue if electric powers shall be integrated
BooleanintegrateCDE (from PartialElectricPowerPlant)simCenter.integrateCDEtrue if CDE shall be integrated
BooleancalculateCost (from PartialElectricPowerPlant)simCenter.calculateCosttrue if costs shall be calculated

Connectors

TypeNameDefaultDescription
TransiEnt.Basics.Interfaces.Electrical.ActivePowerPortepp (from PartialElectricPowerPlant)
TransiEnt.Basics.Interfaces.Electrical.ElectricPowerInP_el_setElectric power setpoint

Components

TypeNameDefaultDescription
TransiEnt.SimCentersimCenter (from PartialElectricPowerPlant)
TransiEnt.ModelStatisticsmodelStatistics (from PartialElectricPowerPlant)
TransiEnt.Components.Statistics.Collectors.LocalCollectors.CollectElectricPowercollectElectricPower (from PartialElectricPowerPlant)
TransiEnt.Components.Statistics.Collectors.LocalCollectors.CollectGwpEmissionsElectriccollectGwpEmissions (from PartialElectricPowerPlant)
TransiEnt.Components.Statistics.Collectors.LocalCollectors.PowerPlantCostcollectCosts (from PartialElectricPowerPlant)
SI.ActivePowerP_el_is (from PartialElectricPowerPlant)-epp.P
RealP_star (from PartialElectricPowerPlant)P_el_is/P_el_n
SI.Efficiencyeta (from PartialElectricPowerPlant)
SI.Timet_fullload (from PartialElectricPowerPlant)E_total_generation/P_el_nfull load time in hours
SI.EnergyE_total_generation (from PartialElectricPowerPlant)Start value for generated electricity statistics
Booleanis_running (from PartialElectricPowerPlant)For continuous plants always true, for discontinous depending on state
SI.EnthalpyFlowRateQ_flow_fuel_is (from PartialElectricPowerPlant)P_el_is/eta
SI.MassFlowRatem_flow_CDE (from PartialElectricPowerPlant)fuelSpecificCO2Emissions.m_flow_CDE_per_Energy*abs(P_el_is)/eta - m_flow_gas_CDE_deposited
SI.MassFlowRatem_flow_gas_CDE_deposited (from PartialElectricPowerPlant)0*time
Realdelta_f_star (from PartialElectricPowerPlant)(epp.f - simCenter.f_n)/simCenter.f_n