modelPartialElectricPowerPlant
Abstract model of an electric power plant with L1 on electric side
Extends from TransiEnt.Basics.Icons.IndustryPlant (Icon for industry plants).
Information
1. Purpose of model
Prototype model for electric power plant models containing all relevant statistic blocks.
2. Level of detail, physical effects considered, and physical insight
L1E (defined in the CodingConventions)
3. Limits of validity
(no remarks)
4. Interfaces
epp: active power port
5. Nomenclature
(no elements)
6. Governing Equations
(no equations)
7. Remarks for Usage
(no remarks)
8. Validation
(no remarks)
9. References
(no remarks)
10. Version History
Model created by Pascal Dubucq (dubucq@tuhh.de) on 01.10.2014
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | nSubgrids | simCenter.iDetailedGrid | For calculation of statistics in subgrids (=1 local grid, e.g. hamburg, =2 surrounding grid, e.g. UCTE grid |
| Physical Constraints | |||
| Modelica.Units.SI.Power | P_el_n | 300e6 | Nominal power of plant |
| Statistics | |||
| Modelica.Units.SI.Efficiency | eta_total | 0.6 | Total efficiency of plant for emission calculation |
| EnergyResource | typeOfResource | EnergyResource.Conventional | Type of energy resource for global model statistics |
| PrimaryEnergyCarrier | typeOfPrimaryEnergyCarrier | PrimaryEnergyCarrier.BlackCoal | Type of primary energy carrier for co2 emissions global statistics |
| Boolean | integrateElPower | simCenter.integrateElPower | true if electric powers shall be integrated |
| Boolean | integrateCDE | simCenter.integrateCDE | true if CDE shall be integrated |
| Boolean | calculateCost | simCenter.calculateCost | true if costs shall be calculated |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| TransiEnt.Basics.Interfaces.Electrical.ActivePowerPort | epp |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| TransiEnt.SimCenter | simCenter | ||
| TransiEnt.ModelStatistics | modelStatistics | ||
| TransiEnt.Components.Statistics.Collectors.LocalCollectors.CollectElectricPower | collectElectricPower | ||
| TransiEnt.Components.Statistics.Collectors.LocalCollectors.CollectGwpEmissionsElectric | collectGwpEmissions | ||
| TransiEnt.Components.Statistics.Collectors.LocalCollectors.PowerPlantCost | collectCosts | ||
| SI.ActivePower | P_el_is | -epp.P | |
| Real | P_star | P_el_is/P_el_n | |
| SI.Efficiency | eta | ||
| SI.Time | t_fullload | E_total_generation/P_el_n | full load time in hours |
| SI.Energy | E_total_generation | Start value for generated electricity statistics | |
| Boolean | is_running | For continuous plants always true, for discontinous depending on state | |
| SI.EnthalpyFlowRate | Q_flow_fuel_is | P_el_is/eta | |
| SI.MassFlowRate | m_flow_CDE | fuelSpecificCO2Emissions.m_flow_CDE_per_Energy*abs(P_el_is)/eta - m_flow_gas_CDE_deposited | |
| SI.MassFlowRate | m_flow_gas_CDE_deposited | 0*time | |
| Real | delta_f_star | (epp.f - simCenter.f_n)/simCenter.f_n |
Contents
| Name | Description |
|---|---|