This is a model to calculate mass flows in typical electrolyzers.
Mass flow is modeled using expressions from Espinosa-López et al 2018. Dependent on stack current and Faraday's efficiency (1 by default).
Original model developed and validated in the range of 20-60 °C with operating H2 and O2 tank pressure of 15-35 bar.
(no remarks)
(no elements)
Mass flow is modeled using Faraday's Law, as in Espinosa-López et al 2018.
(no remarks)
Results have been validated against Espinosa-López et al 2018 published figures.
Manuel Espinosa-López, Philippe Baucour, Serge Besse, Christophe Darras, Raynal Glises, Philippe Poggi, André Rakotondrainibe, and Pierre Serre-Combe. Modelling and experimental validation of a 46 kW PEM high pressure water electrolyser. Renewable Energy, 119, pp. 160-173, 2018. doi: 10.1016/J.RENENE.2017.11.081.
Created by John Webster (jcwebste@edu.uwaterloo.ca) October 2018.