This is a model for AREVA Inc. Giner electrolyzer system temperature.
Temperature is modeled according to Espinosa-López et al 2018 based on heat generated from electrolysis, pump, and heat lost due to convection, cooling system, and enthalpy loss. The contribution of the pump is modeled differently.
Cooling:
Original model developed and validated in the range of 20-60 °C, with operating pressure of 15-35 bar and a maximum cooling power for operating current of 400A.
(no elements)
(no elements)
Consist of thermal equations from Espinosa-López et al 2018 with new PID-cooling power model from ClaRa LimPID block.
(no remarks)
Results have been validated against Espinosa-López et al 2018 published figures.
Manuel Espinosa-López, Philippe Baucour, Serge Besse, Christophe Darras, Raynal Glises, Philippe Poggi, André Rakotondrainibe, and Pierre Serre-Combe. Modelling and experimental validation of a 46 kW PEM high pressure water electrolyser. Renewable Energy, 119, pp. 160-173, 2018. doi: 10.1016/J.RENENE.2017.11.081.
Created by John Webster (jcwebste@edu.uwaterloo.ca) October 2018.