.TransiEnt.Producer.Gas.Electrolyzer.Base.Physics.Voltage.ThermoneutralVoltageModels.V_tn1

Information

1. Purpose of model

This is a model for thermoneutral voltage of electrolysis.

2. Level of detail, physical effects considered, and physical insight

Voltage is modeled according to Espinosa-López et al 2018 .

3. Limits of validity

Original model developed and validated in the range of 20-60 °C with operating pressure of 15-35 bar.

4. Interfaces

(no remarks)

5. Nomenclature

(no elements)

6. Governing Equations

7. Remarks for Usage

(no remarks)

8. Validation

9. References

Manuel Espinosa-López, Philippe Baucour, Serge Besse, Christophe Darras, Raynal Glises, Philippe Poggi, André Rakotondrainibe, and Pierre Serre-Combe. Modelling and experimental validation of a 46 kW PEM high pressure water electrolyser. Renewable Energy, 119, pp. 160-173, 2018. doi: 10.1016/J.RENENE.2017.11.081.

10. Version History

Created by John Webster (jcwebste@edu.uwaterloo.ca) October 2018.