recordBaseElectrolyzerL2Specification

Record used for specification of an Electrolyzer system

Extends from TransiEnt.Basics.Icons.Record (Icon for records).

Information

1. Purpose of model

Partial record for electrolyzer system specific data.

2. Level of detail, physical effects considered, and physical insight

(no remarks)

3. Limits of validity

(no remarks)

4. Interfaces

(no remarks)

5. Nomenclature

(no remarks)

6. Governing Equations

(no remarks)

7. Remarks for Usage

(no remarks)

8. Validation

(no validation or testing necessary)

9. References

(no remarks)

10. Version History

Adopted from BaseCHPRecord. Created by John Webster (jcwebste@edu.uwaterloo.ca) Oct. 2018

Parameters

TypeNameDefaultDescription
Fundamental Definitions
Integern_cells60number of cells in series in the electrolyzer stack
Realalpha_an0.7353charge transfer coefficient for anode
SI.EnergyE_exc52994Activation energy for anode reaction
SI.ChemicalPotentialE_pro10536Temperature independent parameter for activation energy in proton transport
SI.AreaPEM_area290e-4Active surface area of electrolyzer cell electrodes
SI.Currenti_el_n400Nominal current of electrolyzer
SI.ActivePowerP_el_n4.5e4Nominal power of the electrolyzer
SI.ActivePowerP_el_max3*P_el_nMaximum power of the electrolyzer
SI.ThermalResistanceR_th0.0668Thermal resistance of stack
SI.HeatCapacityC_th162116Overall lumped thermal capacitance
SI.CurrentDensityi_dens_0_an_std1.08e-4Exchange current density at electrodes at T_std
SI.Thicknesst_mem178e-6PE membrane thickness
SI.Conductivitymem_conductivity_ref10.31Membrane conductivity value at T_std
RealspecificWaterConsumption10Mass of water per mass of hydrogen
SI.TemperatureT_out283.15Hydrogen output temperature
Cooling circuit
SI.PowerP_el_pump1100pump el power consumption
SI.Efficiencyeta_pumpmotor0.75pump's motor electric efficiency
SI.VolumeFlowRateV_flow_water140/1000/60water flow rate in cooling loop
SI.TemperatureT_op_max273.15 + 55.8max operating temp
SI.TemperatureT_cool_setT_op_max - 10Cooling trigger point
SI.HeatFlowRateQ_flow_cool_max6911Maximum cooling power
Cooling circuits
SI.PressureDifferenceDelta_p_pump2*100000total pump head