Simple static, full modulating gas boiler model with splitted heat generation and emission (CO2) calculation
By default, a given heat duty Qflow,set is set (limited) to the boilers characteristica (Qflow,n, Qflow,min) and then set to a static ideal heat exchanger. For the given heat carrier supply temperature the required heat carrier mass flow is calulated. For the operational mode the supply temperature can also be left variable.
In HoldTemperature-mode the boiler needs no heat flow set-input and will heat the carrier to the given temperature within its limits of power.
From the part load of the boiler and the return flow temperature, the boiler efficiency and fuel heat input is calculated with characteristical lines.
Depending on the users preference (set by the parameter referenceNCV), efficiencies and power calculations in this model are based on either the net or the gross calorific value (NCV or GCV, respectively). With a function for dynamic HV calculation the required fuel mass flow as an output-value is generated.
A constant air ratio to be chosen is asumed.
Q_flow_set_internal - heat duty input (only in default mode)
T_supply_set_internal - temperature input in K
gasPortIn/Out - port for fuelgas at the inlet and exhaustgas at the outlet
waterPortIn/Out - ports for the heat carrier (water)
m_flow_fuel_req - output of required fuel mass flow rate
m_flow_HC - output of heat carrier mass flow rate
5. Nomenclature
6. Governing Equations
(no remarks)
7. Remarks for Usage
(no elements)
8. Validation
(no validation or testing necessary)
9. References
(no remarks)