modelTestHeatpumpWithControl_HeatingSystem

Model for testing HeatpumpWithControl

Extends from TransiEnt.Basics.Icons.Checkmodel (Icon for check models).

Information

1. Purpose of model

Test environment for BivalentHeatpumpWithControl

2. Level of detail, physical effects considered, and physical insight

(Purely technical component without physical modeling.)

3. Limits of validity

(Purely technical component without physical modeling.)

4.Interfaces

(no remarks)

5. Nomenclature

(no elements)

6. Governing Equations

(no equations)

7. Remarks for Usage

(no remarks)

8. Validation

(no validation or testing necessary)

9. References

(no remarks)

10. Version History

Parameters

TypeNameDefaultDescription
TransiEnt.Producer.Heat.Power2Heat.Heatpump.HeatpumpSystemPropertiesparams

Components

TypeNameDefaultDescription
SimCentersimCenter
Modelica.Thermal.HeatTransfer.Components.HeatCapacitorRoom
Modelica.Thermal.HeatTransfer.Sensors.TemperatureSensorT_stor_is
Modelica.Thermal.HeatTransfer.Components.ThermalConductorwall_a
Modelica.Thermal.HeatTransfer.Celsius.PrescribedTemperatureT_amb
TransiEnt.Components.Visualization.PowerSystemBasics.EnergyE_Heatpump
TransiEnt.Components.Visualization.PowerSystemBasics.EnergyE_heatingdemand
Modelica.Blocks.Sources.RealExpressionT_amb_deg_C
Modelica.Blocks.Sources.Constantzero
Modelica.Blocks.Logical.SwitchQ_flow_peakload
Modelica.Blocks.Continuous.LimPIDctrlPeakload
Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlowheatBdryPeakloadFH
TransiEnt.Components.Visualization.PowerSystemBasics.EnergyE_Peakload
Modelica.Blocks.Sources.RealExpressionx_PeakLoad_per_Cent
TransiEnt.Producer.Heat.Power2Heat.Heatpump.BivalentHeatPumpWithControlheatPumpWithControl
Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlowFloorHeatingBdry
Modelica.Blocks.Continuous.LimPIDctrlFloorHeating
Modelica.Thermal.HeatTransfer.Sensors.TemperatureSensorT_room_is
Modelica.Blocks.Sources.ConstantT_room_set
Modelica.Thermal.HeatTransfer.Components.HeatCapacitorStorage
Modelica.Blocks.Tables.CombiTable1DvT_stor_set
Modelica.Blocks.Sources.RealExpressionT_amb1
Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlowheatBdryFloorHeatingDeload
Modelica.Blocks.Math.Gaingain
Modelica.Thermal.HeatTransfer.Components.ThermalConductorwall_storTaken from Knop page 48, Viessmann Vitocell 100-W (200l, 2,2kWh loss per 24h at Delta T 45K)
TransiEnt.Components.Visualization.PowerSystemBasics.EnergyE_storageloss
Modelica.Thermal.HeatTransfer.Sources.PrescribedTemperatureheatBdryPeakloadFH1
Modelica.Blocks.Sources.BooleanExpressionisPeakload

Contents

NameDescription
plotResult