.TransiEnt.Producer.Heat.SolarThermal.Control.ControllerPumpSolarCollectorDeltaT

Information

1. Purpose of model

Controller model to control the pump for a solar thermal collector by the temperature difference of inlet and outlet temperatures.

2. Level of detail, physical effects considered, and physical insight

A hysteresis with the temperature difference models real controller behavior. The onOffRelais avoids having too many switching events. The first order block smoothens the output.

3. Limits of validity

(Purely technical component without physical modeling.)

4. Interfaces

(no remarks)

5. Nomenclature

(no elements)

6. Governing Equations

(no equations)

7. Remarks for Usage

(no remarks)

8. Validation

Tested in TransiEnt.Producer.Heat.SolarThermal.Check.TestCollectorFluidCycle_constProp2.

9. References

(no remarks)

10. Version History

Model created by Fenja Frerichs, Jul 2017

Model modified (first order added, moved PID controller, applied coding conventions) by Carsten Bode (c.bode@tuhh.de), Nov 2018


Generated at 2024-11-21T19:25:40Z by OpenModelicaOpenModelica 1.24.2 using GenerateDoc.mos