recordHeatPumpParameters
(Default) HeatPumpSystem parameters for usage within the GridConstructor
Information
Purpose of model
Accommodates all via GridConstructor adjustable parameters for the heat pump system used in IndependentTechnologies.
Remarks for Usage
Changing the values within the record, will change the default values of the heat pump systems of all consumers equally (as long as no other values are given within your model). To change the parameters of the heat pump system of a single consumer, please use the parameter dialogue of the GridConstructors (tab "HeatPump") within your model.
References
(no remarks)
Version History
Model created during IntegraNet I
Documentation update, January 2025
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| SI.HeatFlowRate | Q_flow_n | 3.5e3 | Nominal heat flow of heat pump at nominal conditions according to EN14511 |
| Real | COP_n | 3.7 | Heat pump coefficient of performance at nominal conditions according to EN14511 |
| String | T_source | "T_ground" | Temperature of heat source |
| SI.Power | P_el_backup | 10e3 | Nominal electric power of the backup heater |
| SI.Temperature | T_storage_min | 303.15 | Minimum storage temperature of heat pump system |
| SI.Temperature | T_storage_max | 313.15 | Maximum storage temperature of heat pump system |
| SI.Volume | V_storage | 0.2 | Volume of the storage of heat pump system |
| SI.Height | h_storage | 0.5 | Height of heat storage in heat pump system |
| Modelica.Units.NonSI.Temperature_degC | T_storage_amb | 15 | Assumed constant temperature in tank installation room in heat pump system |
| SI.SurfaceCoefficientOfHeatTransfer | k_storage | 0.08 | Coefficient of heat transfer through tank surface in heat pump system |