.WasteWater.ASM2d.PreClar.preclar3

Information

This is a special case of the ASM2d static primary clarifier model.
Here measurement data at the end (effluent) of the preclarifier needs to be provided.
This is typical for some real plants. Influent is then calculated.

Parameters:
      - ASM2d conversion factors for calculation of Xtss
  V   - volume of the preclarifier
  aS* - fractions of e.g. COD in influent (soluble components)
  aX* - fractions of e.g. COD in influent (particular components)
  n_corr- correction factor for the efficiency function

Dimension of InPort is 4.
  1 - Chemical Oxygen Demand (COD) at effluent of primary clarifier
  2 - annonium nitrogen (Snh) at effluent of primary clarifier
  3 - phosphorus (Spo) at effluent of primary clarifier
  4 - pH-value at effluent of primary clarifier

Contents

NameDescription
 WWU