modelInfiniteBus

PSAT Infinite Bus

Extends from iPSL.Electrical.Essentials.pfComponent (Partial model containing all the Data for entering Power Flow data).

Information

Development level

3

Reference

None

Last update

2015-12-14

Author

Maxime Baudette, SmarTS Lab, KTH Royal Institute of Technology

Contact

luigiv@kth.se

Parameters

TypeNameDefaultDescription
ComplexvV_0*ComplexMath.exp(ComplexMath.j*angle_0*Modelica.Constants.pi/180)
Power flow data
RealV_b (from pfComponent)400Base voltage of the bus (kV)
RealV_0 (from pfComponent)1Voltage magnitude (pu)
Realangle_0 (from pfComponent)0Voltage angle (deg)
RealP_0 (from pfComponent)1Active power (MW)
RealQ_0 (from pfComponent)0Reactive power (MVAr)
RealS_b (from pfComponent)SysData.S_bSystem base power (MVA)
Realfn (from pfComponent)SysData.fnSystem Frequency (Hz)

Connectors

TypeNameDefaultDescription
iPSL.Connectors.PwPinp

Components

TypeNameDefaultDescription
SystemBaseSysData (from pfComponent)Must add this line in all models
RealPActive Power absorbed by the Infinite bus (MW)
RealQReactive Power absorbed by the Infinite bus (MVAr)
Complexi

Revisions

Copyright 2015-2016 RTE (France), SmarTS Lab (Sweden), AIA (Spain) and DTU (Denmark)

The authors can be contacted by email: info@itesla-ipsl.org

This Source Code Form is subject to the terms of the Mozilla Public License, v. 2.0.

If a copy of the MPL was not distributed with this file, You can obtain one at http://mozilla.org/MPL/2.0.