modelOrder3

Third Order Synchronous Machine with Inputs and Outputs

Extends from BaseClasses.baseMachine.

Information

Development level

2

Reference

Order III Synchonous Machine, PSAT Manual 2.1.8

Last update

September 2015

Author

Joan Russinol, SmarTS Lab, KTH Royal Institute of Technology

Contact

luigiv@kth.se

Parameters

TypeNameDefaultDescription
Power flow data
RealV_b (from pfComponent)400Base voltage of the bus (kV)
RealV_0 (from pfComponent)1Voltage magnitude (pu)
Realangle_0 (from pfComponent)0Voltage angle (deg)
RealP_0 (from pfComponent)1Active power (MW)
RealQ_0 (from pfComponent)0Reactive power (MVAr)
RealS_b (from pfComponent)SysData.S_bSystem base power (MVA)
Realfn (from pfComponent)SysData.fnSystem Frequency (Hz)
Machine parameters
RealSn (from baseMachine)Power rating (MVA)
RealVn (from baseMachine)Voltage rating (kV)
Realra (from baseMachine)Armature resistance (pu)
Realxd1 (from baseMachine)d-axis transient reactance (pu)
RealM (from baseMachine)Machanical starting time (2H), kWs/kVA
RealD (from baseMachine)Damping coefficient
Realxdd-axis synchronous reactance (pu)
RealTd10d-axis open circuit transient time constant (s)
Realxqq-axis synchronous reactance (pu)

Connectors

TypeNameDefaultDescription
iPSL.Connectors.PwPinp (from baseMachine)
Modelica.Blocks.Interfaces.RealOutputdelta (from baseMachine)Rotor angle (deg)
Modelica.Blocks.Interfaces.RealOutputw (from baseMachine)Rotor speed (pu)
Modelica.Blocks.Interfaces.RealOutputv (from baseMachine)Generator terminal voltage (pu)
Modelica.Blocks.Interfaces.RealOutputP (from baseMachine)Active power (pu)
Modelica.Blocks.Interfaces.RealOutputQ (from baseMachine)Reactive power (pu)
Modelica.Blocks.Interfaces.RealInputvf (from baseMachine)Field voltage (pu)
RealOutputvf0 (from baseMachine)Initial field voltage (pu)
RealOutputpm0 (from baseMachine)Initial mechanical power (pu)
Modelica.Blocks.Interfaces.RealInputpm (from baseMachine)Mechanical power (pu)

Components

TypeNameDefaultDescription
SystemBaseSysData (from pfComponent)Must add this line in all models
Realanglev (from baseMachine) Bus voltage angle
Realvd (from baseMachine)d-axis voltage (pu)
Realvq (from baseMachine)q-axis voltage (pu)
Realid (from baseMachine)d-axis currrent (pu)
Realiq (from baseMachine)q-axis current (pu)
Reale1qq-axis transient voltage (pu)

Revisions

iPSL:

Copyright 2015-2016 RTE (France), SmarTS Lab (Sweden), AIA (Spain) and DTU (Denmark)

The authors can be contacted by email: info@itesla-ipsl.org

This Source Code Form is subject to the terms of the Mozilla Public License, v. 2.0.

If a copy of the MPL was not distributed with this file, You can obtain one at http://mozilla.org/MPL/2.0.