modelPV1

Constant PV Generator, Solar Photo-Voltaic Generator

Information

Reference

Constant PV Generator, Solar Photo-Voltaic Generator, PSAT Manual 2.1.8

Last update

September 2015

Author

Joan Russinol, SmarTS Lab, KTH Royal Institute of Technology

Contact

luigiv@kth.se

Parameters

TypeNameDefaultDescription
RealSn10Nominal power (MVA)
Realvref1.0002Voltage reference (pu)
RealTd0.15d-axis inverter time constant (s)
RealTq0.15q-axis inverter time constant (s)
RealKi50.9005Integral gain of the voltage controller
RealKp0.0868Proportional gain of the voltage controller
Power flow data
RealS_b100System base power (MVA)
RealV_01.00018548610126Voltage magnitude (pu)
Realangle_0-0.0000253046024029618Voltage angle (deg)
RealP_00.4Active power (pu)
RealQ_00.3Reactive power (pu)

Connectors

TypeNameDefaultDescription
iPSL.Connectors.PwPinp

Components

TypeNameDefaultDescription
RealvBus voltage magnitude (pu)
RealanglevBus voltage angle (deg.)
Realidref1d-axis current setpoint
Realiqref1q-axis current setpoint
Realidd-axis current (pu)
Realiqq-axis current (pu)
Realvdd-axis voltage (pu)
Realvqq-axs voltage (pu)
RealPActive power (pu)
RealQReactive power (pu)

Revisions

Copyright 2015-2016 RTE (France), SmarTS Lab (Sweden), AIA (Spain) and DTU (Denmark)

The authors can be contacted by email: info@itesla-ipsl.org

This Source Code Form is subject to the terms of the Mozilla Public License, v. 2.0.

If a copy of the MPL was not distributed with this file, You can obtain one at http://mozilla.org/MPL/2.0.