modelPV1
Constant PV Generator, Solar Photo-Voltaic Generator
Information
Reference |
Constant PV Generator, Solar Photo-Voltaic Generator, PSAT Manual 2.1.8 |
Last update |
September 2015 |
Author |
Joan Russinol, SmarTS Lab, KTH Royal Institute of Technology |
Contact |
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | Sn | 10 | Nominal power (MVA) |
| Real | vref | 1.0002 | Voltage reference (pu) |
| Real | Td | 0.15 | d-axis inverter time constant (s) |
| Real | Tq | 0.15 | q-axis inverter time constant (s) |
| Real | Ki | 50.9005 | Integral gain of the voltage controller |
| Real | Kp | 0.0868 | Proportional gain of the voltage controller |
| Power flow data | |||
| Real | S_b | 100 | System base power (MVA) |
| Real | V_0 | 1.00018548610126 | Voltage magnitude (pu) |
| Real | angle_0 | -0.0000253046024029618 | Voltage angle (deg) |
| Real | P_0 | 0.4 | Active power (pu) |
| Real | Q_0 | 0.3 | Reactive power (pu) |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| iPSL.Connectors.PwPin | p |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Real | v | Bus voltage magnitude (pu) | |
| Real | anglev | Bus voltage angle (deg.) | |
| Real | idref1 | d-axis current setpoint | |
| Real | iqref1 | q-axis current setpoint | |
| Real | id | d-axis current (pu) | |
| Real | iq | q-axis current (pu) | |
| Real | vd | d-axis voltage (pu) | |
| Real | vq | q-axs voltage (pu) | |
| Real | P | Active power (pu) | |
| Real | Q | Reactive power (pu) |
Revisions
Copyright 2015-2016 RTE (France), SmarTS Lab (Sweden), AIA (Spain) and DTU (Denmark)
- RTE: http://www.rte-france.com
- SmarTS Lab, research group at KTH: https://www.kth.se/en
- AIA: http://www.aia.es/en/energy
- DTU: http://www.dtu.dk/english
The authors can be contacted by email: info@itesla-ipsl.org
This Source Code Form is subject to the terms of the Mozilla Public License, v. 2.0.
If a copy of the MPL was not distributed with this file, You can obtain one at http://mozilla.org/MPL/2.0.