modelPControl_Type4B_CDV

Active Power Control for IEC Type4B Model. Developed by DTU

Information

Development level

2

Parameters

TypeNameDefaultDescription
Realw_initInitial steady state generator speed
RealT_UfiltVoltage measurement filter time constant
RealdPmaxWind turbine maximum power ramp rate
Realini_PcmdInitial Active Power
Realini_UwttInitial Voltage Magnitude
Realini_iPcmdInitial Active Current Magnitude
RealTpordTime constant in power order lag
RealTpaeroTime constant in aerodynamic power response

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealInputiPmax
Modelica.Blocks.Interfaces.RealInputUwtt
Modelica.Blocks.Interfaces.RealInputw_gen
Modelica.Blocks.Interfaces.RealInputPwtt_ref
Modelica.Blocks.Interfaces.RealOutputiPcmd
Modelica.Blocks.Interfaces.RealOutputimPin

Components

TypeNameDefaultDescription
iPSL.NonElectrical.Continuous.SimpleLagimSimpleLag
Modelica.Blocks.Math.GainimGain
Modelica.Blocks.Nonlinear.LimiterimLimiter
Modelica.Blocks.Sources.ConstantimSetPoint
iPSL.NonElectrical.Continuous.SimpleLagRateLimVarimSimpleLag_varnonwindup
iPSL.NonElectrical.Continuous.SimpleLagimSimpleLag1
Modelica.Blocks.Math.Divisiondivision
Modelica.Blocks.Math.Productproduct
Modelica.Blocks.Math.Productproduct1

Revisions

Copyright 2015-2016 RTE (France), SmarTS Lab (Sweden), AIA (Spain) and DTU (Denmark)