modelPSAT_WT

Wind Turbine Doubly Fed Induction Generator

Information

Development level

2

Reference

WT Doubly Fed Induction Generator, PSAT Manual 2.1.8

Last update

July 2015

Author

Maxime Baudette, SmarTS Lab, KTH Royal Institute of Technology

Contact

luigiv@kth.se

Parameters

TypeNameDefaultDescription
RealPnom10Nominal Power (MVA)
Realfn50Frequency rating (Hz)
Realrho1.225Air Density (kg/m^3)
Realvw_base15Nominal wind speed (m/s)
RealRs_machine0.01Stator Resistance (pu)
RealXs_machine0.1Stator Reactance (pu)
RealRr_machine0.01Rotor Resitance (pu)
RealXr_machine0.08Rotor Reactance (pu)
RealXm_machine3Magnetisation reactance (pu)
RealHm_machine3Inertia (pu)
RealKp10Pitch control gain (pu)
RealTp3Pitch control time constant (s)
RealKv10Voltage control gain (kV)
RealTe0.01Power Control time constant (s)
Reall75Blade length (m)
Realpoles2Number of poles-pair
Realnblades3Number of blades
Realngb0.01123596Gear box ratio
Power flow data
RealV_01Voltage magnitude (pu)
Realangle_0-0.00243Voltage angle (deg.)
RealP_00.0160000000000082Active power (pu)
RealQ_00.030527374471207Reactive power (pu)
RealS_b100System base power(MVA)
RealV_b400Voltage rating kV

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealInputWind_Speed
iPSL.Connectors.PwPinpin

Components

TypeNameDefaultDescription
ElecDynBlkelecDyn
ElecBlkelecCircuit
WindBlkwindBlk1
MechaBlkmechaBlk1
PitchControlpitchControl1
RealVbuselecCircuit.VbusBus voltage magnitude (pu)
RealAnglebuselecCircuit.AnglebusBus voltage angle (deg)
RealPelecCircuit.pActive power (pu)
RealQelecCircuit.qReactive power (pu)

Revisions

Copyright 2015-2016 RTE (France), SmarTS Lab (Sweden), AIA (Spain) and DTU (Denmark)