blockSimpleLagLim

First order lag transfer function block with a non windup limiter

Extends from Modelica.Blocks.Interfaces.SISO (Single Input Single Output continuous control block).

Information

Development level

3

Reference

IEEE Std. 421.5-2005, Annex E

Last update

2015-11-25

Author

Tin Rabuzin,SmarTS Lab, KTH Royal Institute of Technology

Contact

luigiv@kth.se

Parameters

TypeNameDefaultDescription
RealKGain
Modelica.SIunits.TimeT1Lag time constant
Realy_startOutput start value
RealoutMaxMaximum output value
RealoutMinMinimum output value

Connectors

TypeNameDefaultDescription
RealInputu (from SISO)Connector of Real input signal
RealOutputy (from SISO)Connector of Real output signal

Components

TypeNameDefaultDescription
Realstate

Revisions

Copyright 2015-2016 RTE (France), SmarTS Lab (Sweden), AIA (Spain) and DTU (Denmark)

The authors can be contacted by email: info@itesla-ipsl.org

This Source Code Form is subject to the terms of the Mozilla Public License, v. 2.0.