modelImSetPoint

Set Point. 2014/03/10

Information

Development level

4

Reference

Eurostag/Model Editor User's Manual

Last update

2016/04/26 by AIA

Author

RTE-AIA

Contact

modelica@aia.es

This block plays the same part as the Modelica.Blocks.Sources.Constant block, but the output (y) may be modified during the Dynamic Simulation.

This Block is equivalent to spesific SET POINT Block from Eurostag.

Parameters

TypeNameDefaultDescription
RealVVoltage Set Point

Connectors

TypeNameDefaultDescription
iPSL.Interfaces.AddedConnectorsetPointModification
Modelica.Blocks.Interfaces.RealOutputyOutput signal connector