In this record, fitting coefficients are provided for thermodynamic properties at bubble and dew line. For detailed information of these thermodynamic properties as well as the fitting coefficients in general, please checkout AixLib.DataBase.Media.Refrigerants.BubbleDewStatePropertiesBaseDataDefinition . The fitting coefficients are used in a hybrid refrigerant model provided in AixLib.Media.Refrigerants. For detailed information, please checkout AixLib.Media.Refrigerants.Interfaces.TemplateHybridTwoPhaseMediumRecord.
The provided coefficients are fitted to external data by Engelpracht
and are valid within the following range
Parameter |
Minimum Value |
Maximum Value |
Pressure (p) in bar |
1 |
39.5 |
Temperature (T) in K |
233.15 |
370.15 |
The reference point is defined as 200 kJ/kg and 1 kJ/kg/K, respectively, for enthalpy and entropy for the saturated liquid at 273.15 K.
Engelpracht, Mirko (2017): Development of modular and scalable simulation models for heat pumps and chillers considering various refrigerants. Master Thesis