.AixLib.DataBase.Profiles.SetTemperaturesVentilation2perDay

Information

Overview

Mean value per day: 0.5 1/h.

Two ventilation intervales, each 30 Min with an air exchange rate of 12 1/h.

Model can be used for OFD and MFD. On each floor there is a delay in ventilation between rooms of 30 Min.

One day is represented. Make sure you set the startTime - parameter when using in a table as the beginning of the day, regardless of the fact that the simulation starts at that moment.

Concept

Table for Natural Ventilation:

Column 1: Time

Column 2: Ventilation rate for OFD-Livingroom / OFD-Bedroom / MFD-Bedroom

Column 3: Ventilation rate for OFD-Hobby / OFD Children1 / MFD-Children

Column 4: Ventilation rate for OFD-Kitchen / OFH-Children2 / MFD-Kitchen

Column 5: Ventilation rate for OFH-Bathroom / OFH-WC / MFD- Bathroom

Column 6: Ventilation rate for MFD-Livingroom

References

Record is used in model Modelica.Blocks.Sources.CombiTimeTable


Generated at 2024-12-21T19:25:56Z by OpenModelicaOpenModelica 1.24.3 using GenerateDoc.mos