recordEN_MEN412_Linear

Calibrated on OptiHorst heat pump

Extends from AixLib.Fluid.HeatPumps.ModularReversible.Data.TableDataSDF.TableData4DDeltaTCon.VCLibPy.GenericVCLibPy4D (Partial record for 4D VCLibPy data for heat pumps).

Information

References

Römer, Fabian and Fuchs, Nico and Fuchs, Nico and Müller, Dirk, Practical, Near-Optimal Design Rule Extraction for Heat Pumps in Single-Family Buildings (September 03, 2025). Available at SSRN: https://ssrn.com/abstract=5633891

Parameters

TypeNameDefaultDescription
StringdevIde (from Generic)Name of the device
IntegernDim (from Generic)Number of table dimensions
Stringfilename (from Generic)File name of sdf table data
Real[nDim]facGai (from Generic)fill(1, nDim)Additional factor for inputs, e.g. scale relative compressor speed to match values in sdf tables
Booleanuse_TEvaOutForTab (from Generic)=true to use evaporator outlet temperature for table data, false for inlet
Booleanuse_TConOutForTab (from Generic)=true to use Useful outlet temperature for table data, false for inlet
Integer[nDim]outOrd (from Generic)1:nDimChange order of inputs
Stringflowsheet (from GenericVCLibPy)Name of the flowsheet
Stringrefrigerant (from GenericVCLibPy)Name of the fluid
Electrical Power
StringdatasetPEle (from Generic)Dataset name for electrical power
StringdataUnitPEle (from Generic)Data unit for electrical power
String[nDim]scaleUnitsPEle (from Generic)Scale units for electrical power
Condenser heat flow
StringdatasetQCon_flow (from GenericHeatPump)Dataset name for useful heat flow rate
StringdataUnitQCon_flow (from GenericHeatPump)Data unit for useful heat flow rate
String[nDim]scaleUnitsQCon_flow (from GenericHeatPump)Scale units for useful heat flow rate

Revisions

  • December 22, 2025 by Fabian Roemer:
    First implementation (see issue AixLib #1623)