modelVCLib4DAirToWater_OneRoomRadiator
Air to water heat pump with 4D data based on VCLib
Extends from Modelica.Icons.Example (Icon for runnable examples), BaseClasses.PartialOneRoomRadiator (Simple room model with radiator, without a heat pump).
Information
This example demonstrates how to use the AixLib.Fluid.HeatPumps.ModularReversible.RefrigerantCycle.TableData4DDeltaT refrigerant cycle model with dynamic frosting and defrosting models. Please check the associated documentation for further information.
Note, it is important to add the QEva_flow and relHum to the signal bus in order for the frosting models to work properly.
Please check the documentation of AixLib.Fluid.HeatPumps.ModularReversible.Examples.BaseClasses.PartialOneRoomRadiator for further information on the example.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.HeatFlowRate | Q_flow_nominal (from PartialOneRoomRadiator) | 20000 | Nominal heat flow rate of radiator |
| Modelica.Units.SI.Temperature | TRadSup_nominal (from PartialOneRoomRadiator) | 273.15 + 50 | Radiator nominal supply water temperature |
| Modelica.Units.SI.Temperature | TRadRet_nominal (from PartialOneRoomRadiator) | 273.15 + 45 | Radiator nominal return water temperature |
| Modelica.Units.SI.MassFlowRate | mCon_flow_nominal (from PartialOneRoomRadiator) | Q_flow_nominal/4200/5 | Heat pump nominal mass flow rate in condenser |
| Modelica.Units.SI.MassFlowRate | mEva_flow_nominal (from PartialOneRoomRadiator) | Heat pump nominal mass flow rate in evaporator | |
| Modelica.Units.SI.Volume | V (from PartialOneRoomRadiator) | 6*10*3 | Room volume |
| Modelica.Units.SI.MassFlowRate | mAirRoo_flow_nominal (from PartialOneRoomRadiator) | V*1.2*6/3600 | Nominal mass flow rate of room air |
| Modelica.Units.SI.HeatFlowRate | QRooInt_flow (from PartialOneRoomRadiator) | Q_flow_nominal/5 | Internal heat gains of the room |
| Boolean | witCoo (from PartialOneRoomRadiator) | true | =true to simulate cooling behaviour |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| AixLib.BoundaryConditions.WeatherData.Bus | weaBus (from PartialOneRoomRadiator) | Weather data bus | |
| AixLib.Fluid.HeatPumps.ModularReversible.BaseClasses.RefrigerantMachineControlBus | sigBusHeaPum | Bus with the most relevant information for hp frosting calculation |
Components
Revisions
-
August 27, 2024 by Fabian Wuellhorst:
First implementation (see issue #1576)