| AixLib.DataBase.Walls.Collections.BaseDataMultiWalls | wallTypes | | |
| Air volume of room |
| Modelica.Units.SI.Density | denAir | 1.19 | Density of air |
| Modelica.Units.SI.SpecificHeatCapacity | cAir | 1007 | Specific heat capacity of air |
| Dynamics |
| Modelica.Fluid.Types.Dynamics | energyDynamicsWalls | Modelica.Fluid.Types.Dynamics.DynamicFreeInitial | Type of energy balance for wall capacities: dynamic (3 initialization options) or steady state |
| Initialization › Air volume of room |
| Modelica.Units.SI.Temperature | T0_air | 295.11 | Air |
| Initialization › Walls |
| Modelica.Units.SI.Temperature | TWalls_start | Modelica.Units.Conversions.from_degC(16) | Initial temperature of all walls |
| Inner walls › Heat convection |
| AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface | calcMethodIn | AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A | Calculation method of convective heat transfer coefficient at inside surface |
| Modelica.Units.SI.CoefficientOfHeatTransfer | hConIn_const | 2.5 | Custom convective heat transfer coefficient (just for manual selection, not recommended) |
| Inner walls › Longwave radiation |
| AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer | radLongCalcMethod | AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx | Calculation method for longwave radiation heat transfer |
| Modelica.Units.SI.Temperature | T_ref | Modelica.Units.Conversions.from_degC(16) | Reference temperature for optional linearization of longwave radiation |
| Outer walls › Windows |
| DataBase.WindowsDoors.Simple.OWBaseDataDefinition_Simple | Type_Win | | Window parametrization |
| Outer walls › Solar absorptance |
| Real | solar_absorptance_OW | 0.6 | Solar absoptance outer walls |
| Outer walls › Heat convection |
| AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer | calcMethodOut | AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.DIN_6946 | Calculation method for convective heat transfer coefficient |
| DataBase.Surfaces.RoughnessForHT.PolynomialCoefficients_ASHRAEHandbook | surfaceType | DataBase.Surfaces.RoughnessForHT.Brick_RoughPlaster() | Surface type of outside wall |
| Modelica.Units.SI.CoefficientOfHeatTransfer | hConOut_const | 25 | Custom convective heat transfer coefficient (just for manual selection, not recommended) |
| Outer walls › Sunblind |
| Boolean | use_sunblind | false | Will sunblind become active automatically? |
| Real | ratioSunblind | 0.8 | Sunblind factor. 1 means total blocking of irradiation, 0 no sunblind |
| Modelica.Units.SI.Irradiance | solIrrThreshold | 350 | Threshold for global solar irradiation on this surface to enable sunblinding (see also TOutAirLimit) |
| Modelica.Units.SI.Temperature | TOutAirLimit | 293.15 | Temperature at which sunblind closes (see also solIrrThreshold) |
| Infiltration acc. to EN 12831 (airtightness) |
| Boolean | use_infiltEN12831 | false | Use model to exchange room air with outdoor air acc. to standard |
| Real | n50 | 4 | Air exchange rate at 50 Pa pressure difference |
| Real | e | 0.03 | Coefficient of windshield |
| Real | eps | 1.0 | Coefficient of height |
| Dynamic ventilation |
| Boolean | withDynamicVentilation | false | Dynamic ventilation |
| Modelica.Units.SI.Temperature | HeatingLimit | 288.15 | Outside temperature at which the heating activates |
| Real | Max_VR | 10 | Maximal ventilation rate |
| Modelica.Units.SI.TemperatureDifference | Diff_toTempset | 2 | Difference to set temperature |
| Modelica.Units.SI.Temperature | Tset | 295.15 | Tset |