modelCase430
Extends from AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.Case420.
Information
Input Specifications of Case 430 as described in ASHRAE Standard 140:
Difference to case 420:
- Solar absorptance on exterior surface = 0.6
Limitations
The simulated annual cooling load of Case 430 cannot meet the
statistical acceptance ranges given by ASHRAE140 (01.01.2021).
However, cases that do not perform according to the reference values
should not be considered erroneous. They shall be used as indication
for debugging purposes instead.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | airExchange (from PartialCase) | 0.41 | Constant Air Exchange Rate |
| Real | TsetCooler (from PartialCase) | 27 | Constant Set Temperature for Cooler |
| Real | TsetHeater (from PartialCase) | 20 | Constant Set Temperature for Heater |
| Real | internalGains (from PartialCase) | 200 | Constant Internal Gains |
| Components.Types.selectorCoefficients | absInnerWallSurf (from PartialCase) | AixLib.ThermalZones.HighOrder.Components.Types.selectorCoefficients.abs06 | Coefficients for interior solar absorptance of wall surface abs={0.6, 0.9, 0.1} |
| Real | solar_absorptance_OW (from PartialCase) | 0.6 | Solar absoptance outer walls |
| DataBase.Walls.Collections.OFD.BaseDataMultiInnerWalls | wallTypes (from PartialCase) | AixLib.DataBase.Walls.Collections.ASHRAE140.LightMassCases() | Types of walls (contains multiple records) |
| DataBase.WindowsDoors.Simple.WindowSimple_ASHRAE140 | windowParam (from PartialCase) | ||
| Modelica.Units.SI.Area | Win_Area (from PartialCase) | 12 | Window area |
| Boolean | activeHeatingOutput (from PartialCase) | true | Activates blocks connected with HeaterCoolerPI.heatingPower |
| Boolean | activeCoolingOutput (from PartialCase) | true | Activates blocks connected with HeaterCoolerPI.coolingPower |
| Results check › Heating load or max. temperature | |||
| Real[:,:] | tableHeatOrTempMax (from PartialCase) | [0.0, 0.0, 0.0] | Limits to be checked according to ASHRAE 140 |
| String | dispTypeHeatOrTempMax (from PartialCase) | "None" | Letter displayed in icon of results checker |
| Modelica.Units.SI.Time | checkTimeHeatOrTempMax (from PartialCase) | 31536000 | Simulation time when block should check if model results lies in limit range |
| Results check › Cooling load or min. temperature | |||
| Real[:,:] | tableCoolOrTempMin (from PartialCase) | [0.0, 0.0, 0.0] | Limits to be checked according to ASHRAE 140 |
| String | dispTypeCoolOrTempMin (from PartialCase) | "None" | Letter displayed in icon of results checker |
| Modelica.Units.SI.Time | checkTimeCoolOrTempMin (from PartialCase) | 31536000 | Simulation time when block should check if model results lies in limit range |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Blocks.Interfaces.RealOutput | AnnualHeatingLoad (from PartialCase) | in kWh | |
| Modelica.Blocks.Interfaces.RealOutput | AnnualCoolingLoad (from PartialCase) | in kWh | |
| Modelica.Blocks.Interfaces.RealOutput | TransmittedSolarRadiation_room (from PartialCase) | in kWh/m2 | |
| Modelica.Blocks.Interfaces.RealOutput | FreeFloatRoomTemperature (from PartialCase) | ||
| Modelica.Blocks.Interfaces.RealOutput | FreeFloatRoomRadTemperature (from PartialCase) |