modelCO2TransportStep

Model that transport CO2 through buoyancy driven flow

Extends from Annex60.Airflow.Multizone.Validation.ThreeRoomsContam (Model with three rooms for the validation of the multizone air exchange models).

Information

This model is based on Buildings.Airflow.Multizone.Validation.ThreeRoomsContam. In addition, a CO2 source has been added to the left room in the bottom floor. At initial time, all volumes have zero CO2 concentration. At t=3600 seconds, CO2 is added to volWes. As time progresses, the CO2 is transported to the other rooms, and eventually its concentration decays.

Components

TypeNameDefaultDescription
Annex60.Fluid.MixingVolumes.MixingVolumevolEas (from ThreeRoomsContam)
Annex60.Airflow.Multizone.OrificeoriOutBot (from ThreeRoomsContam)
Annex60.Airflow.Multizone.MediumColumncolOutTop (from ThreeRoomsContam)
Annex60.Airflow.Multizone.OrificeoriOutTop (from ThreeRoomsContam)
Annex60.Airflow.Multizone.MediumColumncolEasInTop (from ThreeRoomsContam)
Annex60.Fluid.Sources.FixedBoundaryvolOut (from ThreeRoomsContam)
Annex60.Airflow.Multizone.MediumColumncolEasInBot (from ThreeRoomsContam)
Annex60.Airflow.Multizone.MediumColumncolOutBot (from ThreeRoomsContam)
Annex60.Airflow.Multizone.MediumColumncolWesBot (from ThreeRoomsContam)
Annex60.Airflow.Multizone.OrificeoriWesTop (from ThreeRoomsContam)
Annex60.Airflow.Multizone.MediumColumncolWesTop (from ThreeRoomsContam)
Annex60.Airflow.Multizone.DoorDiscretizedOperabledooOpeClo (from ThreeRoomsContam)Discretized door
Annex60.Fluid.MixingVolumes.MixingVolumevolWes (from ThreeRoomsContam)
Modelica.Blocks.Sources.Constantopen (from ThreeRoomsContam)
Annex60.Airflow.Multizone.MediumColumncol1EasBot (from ThreeRoomsContam)
Annex60.Airflow.Multizone.OrificeoriEasTop (from ThreeRoomsContam)
Annex60.Airflow.Multizone.MediumColumncolEasTop (from ThreeRoomsContam)
Annex60.Fluid.MixingVolumes.MixingVolumevolTop (from ThreeRoomsContam)
Modelica.Thermal.HeatTransfer.Sources.FixedTemperatureTTop (from ThreeRoomsContam)Fixed temperature
Modelica.Thermal.HeatTransfer.Sources.FixedTemperatureTWes (from ThreeRoomsContam)Fixed temperature
Modelica.Thermal.HeatTransfer.Sources.FixedTemperatureTEas (from ThreeRoomsContam)Fixed temperature
Modelica.Thermal.HeatTransfer.Components.ThermalConductorconTop (from ThreeRoomsContam)Thermal conductor
Modelica.Thermal.HeatTransfer.Components.ThermalConductorconWes (from ThreeRoomsContam)Thermal conductor
Modelica.Thermal.HeatTransfer.Components.ThermalConductorconEas (from ThreeRoomsContam)Thermal conductor
Annex60.Fluid.Sensors.TraceSubstancesCO2SenTopCO2 sensor
Annex60.Fluid.Sensors.TraceSubstancesCO2SenWesCO2 sensor
Annex60.Fluid.Sensors.TraceSubstancesCO2SenEasCO2 sensor
Modelica.Blocks.Sources.Pulsepulse
Annex60.Fluid.Sources.TraceSubstancesFlowSourcesouCO2 source

Revisions