Model that checks the correct implementation of the 1st order
derivative of the flow function
This model validates the implementation of
Annex60.Fluid.BaseClasses.FlowModels.basicFlowFunction_m_flow
and its first order derivative
Annex60.Fluid.BaseClasses.FlowModels.basicFlowFunction_m_flow_der.
If the derivative implementation is wrong, the simulation will stop
with an error.
- January 22, 2016, by Michael Wetter:
Corrected type declaration of pressure difference. This is for
#404.
- July 29, 2015, by Michael Wetter:
First implementation.
Generated at 2026-04-04T18:18:28Z by OpenModelicaOpenModelica 1.26.3 using
GenerateDoc.mos