Test model for the extra property sensor
This example tests the sensors that measure trace substances. A
CO2 mass flow rate of 8.18E-8 kg/kg is added to
the volume. The volume also has a fresh air mass flow rate and an
exhaust air mass flow rate. The initial CO2
concentration of the volume is 0 kg/kg. Note that the fresh
air supply has zero carbon dioxide concentration. Therefore, if it
were outside air, then all concentrations are relative to the
outside air concentration.
Contents
| Name |
Description |
Medium |
Medium model |
- May 22, 2015, by Michael Wetter:
Updated example to test the correction for issue
249.
- May 8, 2014, by Michael Wetter:
Added a pressure drop element, as otherwise the initialization
problem is overspecified for incompressible media.
- November 27, 2013 by Michael Wetter:
Changed sink model from a prescribed flow source to a pressure
boundary condition. This is required for the new air model, which
is incompressible. Otherwise, there will be no pressure reference
in the system.
- September 10, 2013 by Michael Wetter:
Changed initialization of volume to fixed initial values to avoid a
translation warning in OpenModelica.
- August 30, 2013 by Michael Wetter:
Renamed example and added an instance of Annex60.Fluid.Sensors.TraceSubstancesTwoPort.
- September 29, 2009 by Michael Wetter:
First implementation.