recordSM_ReluctanceRotorData

Common parameters for synchronous machines with reluctance rotor

Extends from InductionMachineData (Common parameters for induction machines).

Information

Basic parameters of synchronous machines with reluctance rotor are predefined with default values.

Parameters

TypeNameDefaultDescription
Integerm (from InductionMachineData)3Number of phases
Modelica.Units.SI.InertiaJr (from InductionMachineData)0.29Rotor's moment of inertia
Modelica.Units.SI.InertiaJs (from InductionMachineData)JrStator's moment of inertia
Integerp (from InductionMachineData)2Number of pole pairs (Integer)
Modelica.Units.SI.FrequencyfsNominal (from InductionMachineData)50Nominal frequency
RealeffectiveStatorTurns (from InductionMachineData)1Effective number of stator turns
Nominal resistances and inductances
Modelica.Units.SI.ResistanceRs (from InductionMachineData)0.03Stator resistance per phase at TRef
Modelica.Units.SI.TemperatureTsRef (from InductionMachineData)293.15Reference temperature of stator resistance
Modelica.Electrical.Machines.Thermal.LinearTemperatureCoefficient20alpha20s (from InductionMachineData)0Temperature coefficient of stator resistance at 20 degC
Modelica.Units.SI.InductanceLszero (from InductionMachineData)LssigmaStator zero sequence inductance
Modelica.Units.SI.InductanceLssigma (from InductionMachineData)3*(1 - sqrt(1 - 0.0667))/(2*pi*fsNominal)Stator stray inductance per phase
Modelica.Units.SI.InductanceLmd2.9/(2*pi*fsNominal)Stator main field inductance per phase in d-axis
Modelica.Units.SI.InductanceLmq0.9/(2*pi*fsNominal)Stator main field inductance per phase in q-axis
Losses
Modelica.Electrical.Machines.Losses.FrictionParametersfrictionParameters (from InductionMachineData)Friction loss parameter record
Modelica.Electrical.Machines.Losses.CoreParametersstatorCoreParameters (from InductionMachineData)Stator core loss parameter record; all parameters refer to stator side
Modelica.Electrical.Machines.Losses.StrayLoadParametersstrayLoadParameters (from InductionMachineData)Stray load losses
Nominal resistances and inductances › Damper cage
BooleanuseDamperCagetrueEnable / disable damper cage
Modelica.Units.SI.InductanceLrsigmad0.05/(2*pi*fsNominal)Damper stray inductance in d-axis
Modelica.Units.SI.InductanceLrsigmaqLrsigmadDamper stray inductance in q-axis
Modelica.Units.SI.ResistanceRrd0.04Damper resistance in d-axis at TRef
Modelica.Units.SI.ResistanceRrqRrdDamper resistance in q-axis at TRef
Modelica.Units.SI.TemperatureTrRef293.15Reference temperature of damper resistances in d- and q-axis
Modelica.Electrical.Machines.Thermal.LinearTemperatureCoefficient20alpha20r0Temperature coefficient of damper resistances in d- and q-axis